Laboratory syringe pump, transmission accuracy error<±0.5%, can independently control 1~8 channel operation.

Split design, more flexible usage.

7-inch HD color touch screen display and operation, powerful functions, simple operation, rich operating information.

RS485 communication, support MODBUS protocol.

Function and Features

  • Can independentl y control 1~8 channel oper ation
  • 7-inch HD color touch screen display and operation, bringing a good user experience
  • LF-Touch-OS software system, friendly interface, reliable operation
  • Accurate flow control, transmission accuracy error<±0.5%
  • Intelligent flow correction function
  • Four working modes:only infuse, only withdraw, infuse/withdraw, withdraw/infuse
  • With fast filling and emptying function
  • Support start delay and cyclic operation
  • Save five groups of formula parameters
  • RS485 communication, MODBUS protocol, support the setting of communication parameters, convenient to connect with various control device
  • External control signal controls start, stop, pause, and physical isolation
  • Super anti-interference characteristics, wide voltage design, suitable for complex power supply environment
  • High-strength metal case with protective coating, corrosion-resistant and easy to clean
  • The internal circuit is treated with special protection to prevent dust, moisture and static electric            ,        

Controller  technical specifications

CodeLF/TFD/004
Channels1÷4 channels,independently control
Syringe size0.5μl ÷ 60 ml (replace the execution unit)
Syringe selectionBuilt-in mainstream brand syringe specifications, support customization
Working modeInfuse, withdraw ,infuse/withdraw, withdraw/infuse
Error accuracy<±0.5%(>30% of pump stroke)
Flow calibr ationIntelligent guide
Display 7 inch 65565 color LCD 
Display controlTouch screen
Timer 0.1~999 s/min/h
Cycles0~9999
Cycles interv al time0.1~999 s/min/h
Power-down memoryMemorize parameters set before power off
CommunicationRS485,support Modbus protocol
Power suppl yAC100~240V,50Hz/60Hz 
Power consumption40W+30W (each execution unit) 
EnvironmentTemperature range  5~40℃ ,U.R.<80%
Controller dimensions 200×142×88 mm
Controller weight2.0 kg

Technical data Syringe Pump: volume range 5 µl ÷ 1.000 µl

CodeLF/00ZX/01
Range volume Syringes5 μl ÷ 1.000 µl
Flow range0,058 nL/min÷ 1,587 ml/min
Number of configurable units1÷8
Max stroke of pump70 mm
Max rated thrust>2 kgf (regolabile)
Advance per microstep0,198 μm/μstep
Linear speed0,635 μm/min÷ 95,25 mm/min
Dimensions195×43.5×70 mm
Weight0,85 kg