Digital pH electrode

Digital Glass Body pH Electrode with Matching Pin for General Purpose

HN/011311 - Digital Glass Body pH Electrode with Matching Pin for General Purpose

The HN/011311 electrode features a built-in microchip that stores sensor type, serial number, and calibration information.

It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass.

This design consideration is ideal for general purpose laboratory use.

This probe features a 3.5 mm connector designed exclusively to be used with Hanna Instruments Edge Tablet Meters.

  • Matching Pin
  • Double Junction Reference
  • 3.5 mm Connector

Details

The smart chip in edge's digital electrode remembers its last calibration.

Get real-time diagnostics with Cal Check for probe condition and Sensor Check so you will immediately know if the probe is damaged.

The built-in temperature sensor makes automatic temperature compensation standard.

  Matching Pin
The HN/011311 integrates a matching pin into the electrode and is part of the Hanna Instruments Sensor Check™ feature. The matching pin checks the impedance across the indicating and reference electrodes. This allows the edge meter to alert the user in the event that the glass of the indicating pH electrode is cracked and the condition of the reference junction.
  Built-In Microchip
The built-in microchip stores sensor type, serial number and calibration information including date, time, offset, slope, probe condition and buffers used. This information is automatically retrieved by Edge once the electrode is plugged in. The ability to transfer information allows for hot swapping of probes without having to recalibrate. 

All pH measurements are performed within the electrode and transferred digitally to the meter. This overcomes any noise issues associated with the traditional high impedance analog measuring system. Electrical noise can be generated from a built-in temperature sensor and while working in a humid environment.
  Spherical Glass Tip
The spherical shaped tip design allows for a wide area of contact with the measured sample. This permits a faster electrode response with a higher degree of stability. The glass sensing tip on the HI10430 uses Hanna’s high temperature (HT) glass formulation that has a resistance of approximately 400 megaohms. The high impedance makes the HI10430 ideal for aggressive chemical applications and high temperature applications. Conventional glass formulations suffer from a greatly reduced lifespans at high temperatures relative to high temperature glass.
  Double Junction Reference
A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.
  Glass Electrode Body
The glass electrode body is suitable for a wide range of applications due to its chemical resistance. The glass electrode is compatible with many non-aqueous solvents and other aggressive chemicals. Glass is also resistant to many forms of radiation, such as ultraviolet radiation.
  Built-In Temperature Sensor
HN/11310 digital pH probe features a built-in thermistor temperature sensor that is in the tip of the indicating pH electrode. A thermistor temperature sensor provides for a high accuracy temperature reading and should be as close as possible to the indicating pH electrode in order to compensate for the effect that temperature has on the membrane potential. By having an accurate reading it is possible to provide an accurate temperature compensated reading.


Technical specifications

Body Material glass
Reference double
Junction / Flow Rate ceramic, single / 15-20 μL/h
Electrolyte 3.5M KCl
Range pH: 0 to 13
Max Pressure 0.1 bar
Tip Shape spheric (dia: 9.5 mm)
Diameter 12 mm
Body Length / Overall Length 120 mm / 195 mm
Recommended Operating Temperature -5 to 100°C (23 to 212°F)
Temperature Sensor yes
Matching Pin yes
Amplifier no
Digital yes
Cable 1 m (3.3')
Connection 3.5 mm connector
Applications laboratory general purpose