Fluoride LR Checker HC
Provides a simple, accurate and cost-effective way to measure fluoride
HN/000729 - Low Range Fluoride Colorimeter – Checker HC
Improve the accuracy of your water testing results with our simple handheld colorimeter.
With our low range fluoride colorimeter you achieve more precise technology than your standard chemical test kit.
You won’t have to struggle to determine colors visually, our handheld colorimeter eliminates the hassle of matching to a color chart by providing a direct digital fluoride result.
Stock up on reagents! This checker includes a starter kit for 5 tests
- Our portable handheld colorimeter goes where you go
- Get simple results with easy one-button operation
- Don’t waste time matching to a color chart anymore, get direct results quickly
Details
The HN/000729 Checker HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure fluoride.
Fluoride is one of the few chemicals that have been shown to cause significant effects in people through drinking water.
Fluoride has beneficial effects on teeth at low concentrations in drinking water, but excessive exposure to fluoride in drinking water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.
Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay.
Fluoridated water operates on tooth surfaces: in the mouth, it creates low levels of fluoride in saliva, which reduces the rate at which tooth enamel demineralizes and increases the rate at which it remineralizes in the early stages of cavities.
A 1994 World Health Organization expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate. Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride.
Features at-a-glance
- Easier to use and more accurate than chemical test kits
- Dedicated to a single parameter
- Small size, big convenience
- Ideal for: Drinking Water, Environmental, Industrial
Technical specifications
Range |
|
0.00 to 2.00 ppm |
Resolution |
|
0.01 ppm |
Accuracy @ 20°C |
|
±0.05 ppm ±5% of reading |
Light Source |
|
LED @ 575 nm |
Light Detector |
|
silicon photocell |
Environment |
|
0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Battery Type |
|
(1) 1.5V AAA |
Auto-off |
|
after two minutes of non-use and ten seconds after reading |
Dimensions |
|
81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) |
Weight |
|
64 g (2.25 oz.) |
Method |
|
adaptation of SPADNS method |