Choose your language: it-IT en-US
Facebook Twitter Instagram

Leather and Paper pH Portable Meter

Portable pH and temperature meter designed specifically for leather and paper analysis

HN/099171 - Leather and Paper pH Portable Meter

The HN/099171 is a durable, waterproof, and portable pH and temperature meter designed specifically for leather and paper analysis.

Automatic calibration is performed at one or two points with two sets of buffers.

All calibration and measurement readings are automatically compensated for temperature variations.

The HN/099171 uses the HN/01414D glass body, amplified pH electrode that offers numerous features that improve pH testing for surface measurements.

The split-level LCD displays both pH and temperature readings, along with indicators for reading stability, battery percentage, and calibration instructions.

  • Automatic Temperature Compensation
  • Automatic Two-Point Calibration
  • Waterproof

Details

pH measurement of paper, leather, and other surfaces are important during manufacturing and final product stages.

In the paper industry, a pH measurement indicates the chemical stability and permanence of a paper. It is desirable to manufacture paper that has a neutral or slightly basic pH to aid in the preservation of important documents, publications, and artworks.

An acid-free or alkaline paper is able to absorb damaging acid compounds that are naturally formed through aging.

pH of paper and cartons is also important in the food industry.

Food packaging often incorporates antimicrobial agents to inhibit microbial activity during distribution and storage conditions.

The activity of antimicrobial agents can quickly change with a variation in pH. pH compatibility tests consider food composition, chemistry of the antimicrobial agents used, and packaging material.

In leather making, tanning is one of the most chemically complex steps. Generally, tanning creates a leather product that is more breathable, flexible, and suitable for use in handbags, luggage, garments, and a variety of commercial items.

Tanning is performed by a vegetable method or chrome method; chrome-tanned leather requires the addition of chromium salts and a basic component to raise the pH.

The pH of the liquors used in the leather making process and the pH of the final leather product directly affect characteristics such as firmness, heat resistance, and durability.

The HN/099171 uses the HN/01414D amplified pH electrode with glass body.

This specialized electrode offers numerous features that improve surface pH testing.

An integrated temperature sensor allows for temperature compensated pH measurements without the need for a separate temperature probe.

The probe’s flat sensing tip provides optimal surface contact with samples.

An integral part of any pH electrode is the reference junction. The reference junction is a part of the electrode that allows for the flow of ions located in the reference cell into the sample being tested. It is vital that this flow occurs in order to complete an electrical circuit, which ultimately determines the pH value.

Poor contact between the junction and sample will prevent completion of the circuit, resulting in readings that are erratic or constantly drifting.

The flat tip of the HN/01414D provides optimal surface contact between the sample and the junction.

The HN/01414D features an open junction design which utilizes a viscolene reference electrolyte that comes into direct contact with the sample, providing accurate, stable readings.

HI1414D

Glass Body Glass Body

The glass body of the HI1414D is chemically resistant and quick to reach thermal equilibrium, allowing for a faster, more stable response on a wide variety of surfaces.
Flat Tip Flat Tip

The flat tip sensing bulb allows for the direct surface measurement of a sample. The versatility of this tip shape allows pH measurement of samples ranging from leather and paper to cartons and the food it contains.
ATC Open Junction Reference

The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable reading.
ATC Built-In Temperature Sensor

Errors in calibration and measurement are eliminated with the Automatic Temperature Compensation provided by the integrated temperature sensor.

Features-at-a-glance

  • Waterproof - The HN/099171 is a waterproof meter rated IP67 for immersion in up to one meter of water for 30 minutes
  • Automatic Calibration - One or two-point calibration is automatic to two selectable buffer sets
  • Automatic Temperature Compensation – An integrated temperature sensor allows for automatic temperature compensation of pH measurements
  • Multi-Level LCD Display - The split-level LCD displays both pH and temperature readings, along with indicators for reading stability, battery percentage, and calibration instructions
  • On-Screen Tutorial - Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration
  • Battery Error Prevention System - The meter will automatically shut off if there isn’t enough power to obtain an accurate measurement
  • Battery Life Indicator - The battery percent level is displayed at start up alerting the user to the remaining battery power that is available

Technical specification

pH Range -2.00 to 16.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH
pH Calibration automatic, at one or two points with two sets of buffers (standard 4.01, 7.01,10.01 or NIST 4.01, 6.86, 9.18)
Temperature Range -5.0 to 105.0°C / 23.0 to 221.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C (up to 60°C); ±1.0°C (outside) / ±1°F (up to 140°F); ±2.0°F (outside)
Temperature Compensation automatic from -5.0 to 105.0ºC (23 to 221ºF)
Electrode/Probe HN/01414D pre-amplified pH probe with internal temperature sensor, DIN connector and 1 m (3.3’) cable (included)
Battery Type/Life 1.5V (3) AAA / approximately 1200 hours of continuous use; auto-off after 8 minutes of non-use
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)
Weight 205 g (7.2 oz.)
Ordering Information HN/099171 is supplied with HN/01414D flat tipped pH/temperature probe, HN/070004 pH 4.01 buffer solution sachet (20 mL), HN/070007 pH 7.01 buffer solution sachet (20 mL), HN/700680 electrode cleaning solution for cellulose deposits sachets (2 x 20 mL), HN/070960 conductive electrolyte solution for pH measurement (30 mL), batteries, instructions and hard carrying case.