TDS-Tester (0,00÷10,00 ppt)

High-range total dissolved solids tester than can measure up to 10.00 ppt (g/l)

HN/098302 -  Waterproof TDS Tester (0,00÷10,00 ppm)

The HN/098302 is a high-range total dissolved solids tester than can measure up to 10.00 ppt (g/L).

The HN/098302 is a rugged and reliable pocket-sized tester for use in the lab or field.

This modern looking meter is only 0.7" thick and extremely ergonomic, fitting comfortably in your hand.

This tester keeps things simple with a two-button operation; one for ON/OFF, the other for calibration.

  • Large Multi-level LCD
  • Exposed Temperature Probe for Fast Response
  • Simple Two-Button Operation

Details

The HN/098302 features a large multi-level LCD which displays both TDS and temperature readings simultaneously.

The TDS readings are displayed with a 0.01 ppt (g/L) resolution and with an accuracy of ±2% full scale.

The TDS range of the HN/098302 is from 0.00 to 10.00 ppt (g/L).

An exposed temperature sensor allows for rapid automatic temperature compensated TDS measurements.

Temperature can be set to display in ℃ or ℉. The LCD screen has stability and calibration tag indicators.

The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.

TDS readings are performed by an amperometric graphite electrode that resists oxidation, providing better repeatability in measurements.

The use of graphite also reduces the polarization effect common with amperometric testers that use two stainless steel pins.

Calibration is performed by pressing the dedicated calibration button. Once in calibration mode, submerge the probe in 6.44 ppt calibration standard.

When the standard value is recognized and stability reached, the meter will automatically accept and store the calibration value.

Setup options include automatic shut-off timing and temperature unit displayed.

Automatic shut-off options are to turn the meter off after 8 minutes, 60 minutes, or disabled.

To enter the setup mode the user presses a button located in the battery compartment.

Multi-Level LCD - The large LCD displays TDS, temperature, calibration tag, battery level and instability indicator.

Exposed Temperature Probe - An exposed temperature probe allows for an extremely fast and stable TDS measurement.

Two-Button Operation - Only two buttons for meter operation. One for on/off and one for calibration.

Features/Benefits

Slim, Ergonomic Design

  • With rounded edges and a case that is only 17 mm (0.7”) thick, the HI98302 is thin and fits comfortably in the hand or pocket.

Large Multi-level LCD

  • The LCD is 29 mm (1.125”) x 20 mm (0.81”) allowing the user to easily read both TDS and temperature simultaneously.

Two-button Operation

  • One for ON/OFF, the other for calibration.

Exposed Temperature Sensor

  • Exposed temperature sensor allows for quick Automatic Temperature Compensated measurements. Temperature can be displayed in either oC or oF.

Graphite Sensor

  • Reduces polarization effects and does not oxidize resulting in a reliable and accurate reading.

Automatic Calibration

  • Automatic calibration at 1382 ppm (mg/L) with a single push of a button.

Stability Indicator

  • A clock tag stability indicator will disappear to alert the user when the reading is stable.

Automatic shut-off

  • User-selectable time until meter shuts off to conserve battery life. Options are 8 min, 60 min or disabled.

Low Battery Indicator

  • Low battery indicator that is displayed when less than 10% battery life is remaining.

Battery % Level at Startup

  • At start-up, all the LCD segments are displayed for 1 second, then the percent indication of the remaining battery life is displayed.

Technical specifications

TDS Range 0.00 to 10.00 ppt (g/L)
TDS Resolution 0.01 ppt (g/L)
TDS Accuracy ±2% F.S.
Temperature Range 0.0 to 50.0°C / 32.0 to 122.0°F
Temperature Resolution 0.1°C; 1°F
Temperature Accuracy ±0.5°C /±1°F
Calibration automatic, one-point
Temperature Compensation automatic from 0 to 50°C (32 to 122°F)
TDS Conversion Factor 0.5
Battery Type/Life CR2032 3V Li-Ion (1 pc.) / approximately 250 hours of continuous use
Auto-off after 8 minutes, 60 minutes, disabled
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)
Weight 68 g (2.4 oz.) without battery
Ordering Information HN/098302 is supplied with protective cap, 6.44 ppt calibration solution sachet (4), CR2032 battery, instrument quality certificate and instructional manual.