pH/mV/T Meter (0,01 pH) with CAL Check

Benchtop meter features CAL Check™, data logging capability, and USB port for computer connectivity

HN/002221-02  - Benchtop pH/mV Meter with CAL Check

The HN/002221-02 is an affordable pH/mV benchtop meter that features automatic pH calibration up to five-points that can be performed using seven standard buffers.

All pH measurements are compensated for temperature effect automatically with the supplied HN/007662 temperature probe.

The HN/002221-02 can also measure oxidation reduction potential (ORP) in the mV range using ORP electrodes.

The HN/002221-02 offers many features including CAL Check, data logging up to 100 records, GLP (Good Laboratory Practice) capabilities, and PC connectivity via USB to provide users with a simple way to organize and manage their data.

  • Automatic Temperature Compensation
  • GLP and Logging Capabilities
  • CAL Check

Details

The HN/002221-02 pH/mV benchtop meter features CAL Check, data logging capability, and USB port for computer connectivity.

Readings for pH can be manually or automatically compensated for temperature variations with the separate HN/007662 temperature probe from -20.0 to 120.0°C.

As a pH meter, the HN/002221-02 can perform up to a five-point pH calibration with seven standard buffers (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, and 12.45).

The HN/002221-02 can also measure using ORP electrodes (pH channel input), due to the capability to measure mV with a resolution up to 0.1 mV.

The memory of the HN/002221-02 allows for storage of up to 100 log-on-demand records. Logged data, along with Good Laboratory Practice (GLP) data, can be recalled on the meter itself or transferred to a PC via USB cable.

Features at-a-glance

Simple User Interface

  • Operation is simple with limited features that only require the use of a couple of buttons
  • Readings are easy to view on the large, clear display

CAL Check

  • Exclusive CAL Check diagnostics system ensures accurate pH readings every time by alerting users of potential problems during the calibration process
  • The CAL Check system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated pH buffer solutions during calibration
  • After the guided calibration process, the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status

Automatic Calibration

  • Automatic pH calibration can be performed at up to 5 points using 7 standard buffers (1.68, 4.01, 6.86, 7.01, 9.18,10.01, and 12.45)

GLP Data

  • The calibration data for each channel including date, time, standards used, offset, and slope can be accessed when the instrument is in pH measuring mode

HN/01131P pH Electrode

  • The HN/002221-02 is supplied with the HN/01131P glass body, double junction, refillable pH electrode with a BNC and pin connector
  • This design consideration is ideal for laboratory samples, liquid samples, and high temperature samples, as well as general purpose use

Temperature Compensation

  • The HN/002221-02 offers manual or automatic temperature compensation of pH measurements over a wide range from -20.0 to 120.0°C

mV mode

  • The HN/002221-02 has a mV mode that can be used with ORP electrodes and for relative mV readings

Stability Indicator

  • The HN/002221-02 features a stability indicator
  • An hourglass appears on the display when there is instability in the reading
  • The hourglass disappears once the reading has stabilized
  • At that time a reading should be taken or stored

Data Logging

  • The log-on-demand feature allows up to 100 data points to be recorded

Data Transfer 

  • Data can be transferred to a PC with a USB cable and HI92000 software (both sold separately)

pH

pH Range -2.0 to 16.0 pH
pH Resolution 0.01 pH
pH Accuracy ±0.01 pH
pH Calibration automatic, up to five point calibration with seven standard buffer available (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
pH Temperature Compensation Manual or Automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)
pH CAL Check (electrode diagnostics) Yes
pH Input impedence 1012 Ohm


mV

mV Range ±699.9 mV; ±2000 mV
mV Resolution 0.1 mV (±699.9 mV); 1 mV (±2000 mV)
mV Accuracy ±0.2 mV (±699.9 mV); ±1 mV (±2000 mV)

Meter Temperature

Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution 0.1°C
Temperature Accuracy ±0.2 °C (Excluding probe error)


General Meter

pH Electrode HI1131P glass body pH electrode with BNC + Pin connector
Logging Memory log-on-demand up to 100 records
Connectivity opto-isolated USB
Power Supply 12 VDC adapter
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)
Ordering Information HN/002221 is supplied with HN/01131P pH electrode, HN/007662 temperature probe, HN/076404N electrode holder, HN/070004 pH 4.01 buffer solution sachet, HN/070007 pH 7.01 buffer solution sachet, HN/07071S electrolyte solution, HN/700661 cleaning solution sachet, 12 VDC adapter, and instructions.