Choose your language: it-IT en-US
Facebook Twitter Instagram

"Edge-Blu" ph Bluetooth technology

Edge blu, a pH meter that uses pH electrodes with Bluetooth Smart technology

Free yourself from wires when performing pH measurements. Hanna Instruments is proud to introduce Edge blu, a pH meter that uses pH electrodes with Bluetooth Smart technology (Bluetooth 4.0).

These pH electrodes connect wirelessly to edgeblu or a compatible Apple or Android® device running the Hanna Lab App.

  • Edge blu uses HALO Bluetooth pH electrodes with a built-in temperature sensor to send measurement data wirelessly to the meter or a compatible Apple or Android device running the Hanna Lab App
  • Edge blu features advanced pH electrode diagnostics to ensure worry free measurements. Diagnostics include Hanna’s exclusive CAL Check feature that alerts users to potential problems during calibration
  • Edge blu features a capacitive touch keypad that gives a distinctive, modern look. The keypad is sensitive enough to be used with laboratory gloves and has a fast response

The edge blu is thin and lightweight, measuring just 0.5” thick and weighing less than 9 ounces. edge blu has an incredibly wide viewing angle, 5.5” LCD and a sensitive capacitive touch keypad. edge blu is simple to configure, calibrate, measure, log and transfer data to a computer or a USB drive. This meter features Hanna’s exclusive CAL Check to warn if the HALO pH electrode being used is not clean or if your buffers are contaminated during calibration. An Indicator is also displayed after calibration showing the overall probe condition that is based on the offset and slope characteristic of the pH electrode.

The versatile design of edge blu makes equally at home in your hand, on a lab bench, or mounted on a wall.

  Cradle and Electrode Holder
edge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimum viewing angle.
  Wall Mount
Using the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built-in connector to power edge and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.
  Large, Easy to Read LCD
edge blu features an LCD that measures 5.5” and is clearly viewable from over 5 meters. Add to that a wide viewing angle of 150 degrees and you have one of the clearest LCDs in the industry. In addition to its large LCD, edge also features full text guides displayed on the bottom of the screen. There is no need to decipher scrambled abbreviations.
  Capacitive Touch
edge blu features sensitive capacitive touch buttons for accurate keystrokes when navigating edge’s menus and screens. Since they are part of the screen, the buttons can never get clogged with sample residue.
  Bluetooth Digital pH Electrodes
Edge blu uses HALO Bluetooth digital pH electrodes. Once a probe is connected, all sensor information including sensor operating specifications and calibration information is transferred. pH electrodes are easy to exchange when you want to change from measuring with one type to another without the need for recalibration.
  Up to Five-Point pH Calibration
In standard mode, edgeblu can be calibrated automatic up to 5 points with 7 standard buffers (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and 2 custom buffers.
  Good Laboratory Practice (GLP) feature
The GLP data can be review at anytime at a push of a button. GLP data includes, date, time, buffers, offset and slope of the last pH calibration.
  CAL Check pH Electrode Monitoring Technology
Exclusive CAL Check feature analyzes the pH electrode response in the pH buffers during the calibration process to alert the user of potential problems such as contaminated buffer and clean electrode. After calibration, indicators for probe condition is displayed on the measurement screen. The probe condition is based on offset and slope characteristics of the pH electrode.
  Multiple Data Logging Modes
Log-on-demand, log-on-stability, and interval logging modes are all available. Up to 200 data points can be logged on demand and an additional 200 data points for samples logged upon a stable reading. Interval logging is adjustable from 5 seconds to 180 minutes. Up to 600 records can be stored in a maximum of 100 interval lots. Logging modes can be started from the meter or by simply pressing the button on the HALO pH probe.
  Dual USB Ports
Edge blu can be connected to a computer or USB flash drive for transferring logged data. The micro USB port can also be used to charge the meter.

Rechargeable Battery - edgeblu has a built in rechargeable battery that is charged when the meter is in the plugged in benchtop or wall mount cradle. The battery can also be recharged through the micro USB port with either a USB port from a computer or directly to the power supply.

pH Specifications

pH Range -2.000 to 16.000 pH (Standard Mode), -2.00 to 16.00 pH (Basic Mode), ±1000 mV
pH Resolution 0.001 pH, 0.01 pH, 0.1 mV
pH Accuracy (@25ºC/77ºF) ±0.2 mV, ±0.01 pH, ±0.002 pH
pH Calibration 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers;  3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01
pH Temperature Compensation ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*

Temperature Specifications

Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F
Temperature Resolution 0.1 °C, 0.1 °F
Temperature Accuracy ±0.5 °C, ±0.9 °F
°C/°F Yes

Additional Specifications

GLP Yes
Logging stores up to 1000 records: 200 records (log-on-demand and stability logging)
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Power Supply 5 VDC adapter (included)
Dimensions 202 x 140 x 12 mm (7.9” x 5.5” x .05”)
Weight 250 grams (8.82 oz.)
Ordering Information HI2202 edge® blu includes benchtop docking station with electrode holder, wall mount cradle, USB cable, HI11102 glass body, gel filled pH electrode with temperature sensor, pH 4 buffer solution sachets, pH 7 buffer solution sachets, pH 10 buffer solution sachets, electrode cleaning solution sachets, 5 VDC power adapter, instruction manual and instrument quality certificate.

Electrode Specifications

Reference double, Ag/AgCl
Junction / Flow Rate ceramic
Electrolyte gel
Tip Shape spheric
Connection Bluetooth Smart (Bluetooth 4.0), 10 m (33') range
Recommended Operating Temperature -5 to 80°C (23 to 176°F)
Temperature Sensor integrated
Body Material glass

Hanna Lab App Specifications

Range -2.000 to 16.000 pH / ±800 mV / -20.0 to 120.0 ºC *(will be reduced to actual probe/sensor limits)
Resolution 0.1, 0.01, 0.001 pH / 1, 0.1 mV
Accuracy (@25ºC/77ºF) ±0.005 pH / ±0.3 mV
Calibration Points Up to five points with seven standard buffers
Calibration Buffers 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH
Temperature Compensation Automatic from -5.0 to 100.0 ºC / 23.0 to 212.0 ºF *(will be reduced to actual probe/sensor limits)
Compatibility/System Requirements Android: Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later.

iOS: Compatible with iPad (3rd generation or newer), iPhone (4S or newer), iPod Touch (5th generation or newer)
Download Information Hanna Lab App is available free from the Play Store or App Store

 

HALO  pH electrodes with Bluetooth® Smart Technology

HALO Wireless Water pH Meter has a glass body, spherical tip, and has a built-in temperature sensor. All readings are transmitted directly to your Apple or Android device or the edge blu.

  • Take laboratory grade pH and temperature measurements using your smart phone or tablet
  • Easily connect to the Hanna Lab App at the press of a button via Bluetooth wireless technology
  • Group your data by time or notation. Email it for storage or share it with friends or colleagues

The HALO Wireless Water pH Meter incorporates Bluetooth® Smart technology with an application-specific design. There are several features that make it ideal for measuring the pH of water.

 

General Purpose Glass Formulation
General Purpose (GP) glass provides the best response over the entire pH range and can be used for a wide range of applications.

 

Built-In Temperature Sensor
HN/010482 features a built-in temperature sensor for temperature measurement and compensation.

 

Spheric Glass Tip
The spheric bulb is for general purpose use within laboratory environments and applications that measure aqueous solutions due to its large surface area.

  

 

Real-Time Data
Display of pH and temperature updated every second. Readings are automatically saved to a history file every hour, limited only by the available memory on the device.

 

Fluid, Dynamic Graphing
Measurements can be displayed alone on the display, with tabulated data, or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.

 

GLP (Good Laboratory Practice)
Displays date and time of current calibration, offset, and average slope, along with calibrated buffers, mV values, temperature and slopes between each buffer.

 

Calibration Reminder & Measurement Alarms
The Hanna Lab App alerts you when HALO needs calibration or if a measurement threshold is exceeded.

 

Log & Share Data
Saved log files may be annotated with measurement-specific information. Data is easily shared via email in CSV format.

 

Help & Tutorials
Demo mode helps you explore features of the Hanna Lab App. General app information, HALO information, pH tutorial, maintenance tutorial, and contact information are available in help.

HALO Features/Benefits


Connects to Hanna Lab App with a compatible Apple or Android Device via Bluetooth Smart Technology (Bluetooth 4.0)

Up to five-point pH calibration with seven standard pH buffers available

Calibration reminder

  • Alerts you when HALO needs calibration
  • Appropriate preprogrammed calibration buffer set for application specific Halo pH electrodes

Real-time data

  • Displays pH and temperature updated every second

Basic Good Laboratory Practice (GLP)

  • Displays date and time of current calibration along with offset and average slope

Full GLP

  • Displays date and time of current calibration, offset and average slope along with calibrated buffers, mV values, temperature and slopes between each buffer

Fluid, dynamic graphing

  • Measurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing

Measurement alarms

  • Alerts you if the measurement threshold is exceeded

One button sample tagging

  • Pressing either the icon in the Hanna Lab App or button on the HALO will tag sample data for easy reference

Data logging with custom annotations

  • Saved log files may be annotated with measurement specific information
  • Data is autosaved every hour

Four ways to save and share data

  • All data since last autosave
  • Annotations only
  • All data within a timed interval
  • Annotations only within a timed interval

Share data via email in CSV format

Help and tutorials

  • Demo mode to help explore features of the Hanna Lab App
  • General app information
  • General HALO information
  • pH tutorial
  • Maintenance tutorial
  • Contact information

Compatibility

HALO is compatible with the following devices:

  • Android
    Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later.
  • iOS
    iPad (3rd generation or newer)
    iPhone (4S or newer)
    iPod Touch (5th generation or newer)
  • HN/002202 edgeblu Meter

You might also be interested in these items
all rights reserved © 2017 CHEIMIKA SAS DI HEIM JURGENYour purchases are guaranteed by the major lenders